- RomRaider 1.0.0 DEC01 2023 - Open-Source ECU Tuning and Logging -- www.romraider.com PLEASE MAKE SURE TO READ RELEASE _NOTES.TXT_ EACH TIME YOU DOWNLOAD A NEW VERSION OF ROMRAIDER. IMPORTANT NOTICES, KNOWN ISSUES AND NEW FEATURES WILL BE DISCUSSED. RomRaider is a full featured Engine Control Unit editing application for tuning virtually any manufacturer, meant to be used in conjunction with ECU flash and dump utilities. RomRaider will give you full control over timing, fuel, boost and many other parameters in your ECU, competing with very expensive and proprietary software. RomRaider will remove your need for piggyback systems designed to control these functions, and, in most cases, work as well as or better than any stand alone engine management. Reflashing your stock ECU also has the added benefit of a manufacturer tested base map, giving you top notch performance and saving time tuning idle and low throttle applications while retaining all of the benefit of the research and development manufacturer's spend millions of dollars on. RomRaider is currently in BETA TEST status, meaning it is not thoroughly tested and not intended for use by inexperienced users. In addition to being incomplete and untested, only experienced tuners with the required tools (ie, wideband oxygen sensor) should modify an ECU image. As with any engine management, changes could result in severe engine damage. Use at your own risk. Documentation is available at http://wiki.romraider.com and the official RomRaider FAQ can be found at http://www.romraider.com/about444.html. Please be aware that as RomRaider is still in beta status and changing frequently, documentation may be incomplete or out of date. -------------------------------------------- - 1.0.0 DEC01 2023 Notes (12/01/2023) - -------------------------------------------- This is the latest release of RomRaider from the GitHub repo: https://github.com/RomRaider/RomRaider -------------------------------------- - 1.0.0 DEC01 2023 Known Issues - -------------------------------------- - Logger - Gauge min/max/step limits incomplete in logger.xml - ECU connections under Linux are flaky (start the logger after you've started the engine) - Update latency via injector tab broken for some models (eg. 2007 2.5i) - Switching between SSM, OBD, DS2 and NCS protocol mode may not update the parameter list completely. A Logger restart will update the list correctly. Status of these items and more can be viewed at: https://github.com/RomRaider/RomRaider/issues?labels=bug&state=open -------------- - Change Log - -------------- 1.0.0 DEC01 2023 Notes (12/01/2023) ---------------------------------- - Editor - Updates parent table when scale is changed in 1D tables - Fix table sizing bug and add xdfconstant support - Fix table opening bug, Fix Table1D axis label bug; Fix double loaded documents; Improve XDF support - Add JDF/VDF conversion layer - Add shortcut for raw scale, Add number of checksums in status bar - Add DTCs - Fix VDF scaling name error; Fix save definition bug - Add alpha version of dataflow simulation - Improve rendering performance; Dataflow bugfixes - Logger - Fix issue #217, serial RTS for Openport 1.x cables 0.9.4 MAY23 2022 Notes (05/23/2022) ---------------------------------- - Editor - Fix issue #192, table display with modified axis length 0.9.3 MAY20 2022 Notes (05/20/2022) ---------------------------------- - Editor - Add ROM tree sorting option - Fix GUI refresh on User level change - Screen Editor definition files - Display User level warning for Switch tables 0.9.2 MAY07 2022 Notes (05/07/2022) ---------------------------------- Prepare to support Java 6 thru 11 Remove unneeded libraries Prepare for limited 64bit Java support - Editor - More performance improvements - XDF definition support - Improve Bitwise Switch map support - Fix compare images - Fix Nissan checksum issue #184 - Logger - J2534 library cleanup, better support for Linux J2534 - Replace RXTXcomm with JSerialComm 0.9.1 APR26 2022 Notes (04/26/2022) ---------------------------------- Prepare to support Java 6 thru 11 Remove unneeded libraries Prepare for limited 64bit Java support - Editor - More performance improvements - XDF definition support - Improve Bitwise Switch map support - Fix compare images - Logger - J2534 library cleanup, better support for Linux J2534 - Replace RXTXcomm with JSerialComm 0.9.0 APR18 2022 Notes (04/18/2022) ---------------------------------- Prepare to support Java 6 thru 11 Remove unneeded libraries Prepare for limited 64bit Java support - Editor - More performance improvements - XDF definition support - Improve Bitwise Switch map support - Logger - J2534 library cleanup, better support for Linux J2534 - Replace RXTXcomm with JSerialComm 0.8.2 DEC04 2021 (12/04/2020) ---------------------------------- - Editor - Restored Definition Manager directory filter 0.8.1 NOV27 2021 (11/27/2020) ---------------------------------- - Logger - Logger fails to connect when the computer has no COM ports defined - Editor - Restored Logger launch menu item 0.8.0 NOV14 2021 (11/14/2020) ---------------------------------- - Logger - Nissan CAN Logger implementation - Fixed dyno locale problem - Fixed timestamps, dyno def warning, NaN loading, null pointer exceptions - Refined NCS protocol processing in prep for NCS CAN logging, NCS ECU ID is now 6-bytes - Editor - Fixed copy paste issue and reversed copying - Performance improvement - Changed Bosch axis layout to dataLayout='bosch_subtract' - Implemented subcategories with // - Editor redesign - Added Bosch axis layout - Enabled xml parser to use xinclude - Corrections to ALT2 16-bit checksum after code tests - Expand NCS ECU ID to 6 bytes - Adjust RomServer socket number, fix for issue #88 0.7.2 NOV11 2020 (11/11/2020) ---------------------------------- - Logger - Fix reversed colours in LTV 0.7.1 AUG16 2020 (08/06/2020) ---------------------------------- - Logger - Added missing locale translation entries - Fix ECU/TCU relabelling of ECU ID in Logger GUI 0.7.0 MAY28 2020 (05/28/2020) ---------------------------------- - Logger - (GTO2013) Refine support for ELM327 based cables - DS2 protocol now supports "Telegram", logging arbitrary addresses, requires a new logger definition v352 or later to take advantage of this mode 0.6.1 APR25 2020 (04/25/2020) ---------------------------------- - Editor - Fix TableBitwiseSwitch not populating, issue #100 - Logger - (GTO2013) Add initial support for ELM327 based cables for CAN bus, PR #99 0.6.0 APR6 2020 (04/06/2020) ---------------------------------- RomRaider GUI is now ready for translation. Visit https://github.com/RomRaider/RomRaider/wiki/GUI-Translation to see the guide. - All GUI text moved to resource bundle property files under i18n - Editor - Change RomServer TCP port, issue #88 - (GTO2013) Save Fine Course Values when Switching Tables, issue #61 - (GTO2013) Implemented Maskable and Switchable 2D Tables - (stirkac) Added bitwise map editing - Expand MS42 address range, fix for issue RomRaider#90 - Implement overlay enhancement to highlight current cell, issue #71 - Added support for values encoded in SH-2A MOVI20 instruction - Logger - Added Nissan logging support via J2534 cable using K-line - Update Dyno tab to support different Throttle parameters - Create SSM Learning table properties file - Add the ability to read table names from properties file - Enable a warning panel when a 64-bit JRE is detected - Split SSM LTV queries into two sets to fix issue #72 - Change LM2 MTS plugin to poll mode by default - Fix Learning Tables View showing incorrect table axis values: issue#67 0.5.9 RC3 (09/28/2016) ---------------------------------- - Editor - Corrected a number of minor bugs with table copy/paste and overlay logging - Enhanced table copy for non-contiguous cells and copy of overlay values if active - Other optimizations to reduce ROM load time 0.5.9 RC2 (04/29/2015) ---------------------------------- - Logger - Changed the way the Logger definition update or protocol change is handled 0.5.9 RC1 (04/21/2015) ---------------------------------- - Editor - Implement a global endian attribute in ECU definitions overriding table specific endian settings - Rename SSM menu item as the Test App is no longer SSM specific - Allow user to specific read block size in Editor Test App - Fix for RomTree expand/collapse issue - Fix for reversed min/max table colours - Fix for table 3D view min/max ranges - Changed Settings file search order for better portability, starting directory is searched before user's home - Added a missing ECU definition file Dialog to warn user to correct - Added a catch-all exception notification branch - Fix for category node open issue, Double click on node causes the node to open and then close - Changed code to use true Linear Interpolation rather than even cell distance distribution - Added warning log when a static table contains a storageType != 0 - Added ability to parse and save the static table data if the storageType != 0 - Logger - Add -logger.touch to make the Logger UI more 'touch' friendly - BMW DS2 protocol implementation for MS41, MS42 and MS43 DME - Implement DS2 Learning (Adaptation) Table Values read functionality - Added DS2 adaptation reset tool - Group individual DS2 ECU queries into a single memory read start address and length query - Add APSX D1|D2 Wideband O2 Externals Plugin - Added support for the ECOTRONS ALM wideband O2 controller - Allow setting event mode or polled mode in the lm2_mts.plugin Properties file - Implement endian processing in the data converter defined in logger definition - Update Logger definition DTD for new elements of DS2 protocol - Added new protocol selection menu populated with all the protocols defined in the Logger definition file - Add protocol to query status message display - Add support to use Linux Openport 2.0 library if available - Add serial data bit and parity configuration setting items - Added a new BitWise Logger converter to process bits in query results, see Java source file for usage details com/romraider/util/BitWise.java 0.5.8 RC1 (05/31/2014) ---------------------------------- - Editor - Improved ROM image compare functions - Memory utilization improvements - Updates to Save As Repository option - New Settings to customize table open/close and focus - New Settings to customize where tables open on the screen - New Settings for data cell select and highlight colours - Map colourization is no longer automatic when a cell is changed. Use the new button to re-colour the table after changes are made - Cell Tool-Tip displays real value of cell data - Fixed adding/removing associations - Added ability to Ctrl+Alt+Click(Drag) to un-select cells - Support added for multiple table scaling units. With a compatible ECU definition a user can select axis and/or data unit scaling such as imperial or metric, etc. A sample ECU def can be found here: https://raw.githubusercontent.com/scotthew/SubaruDefs/MultipleScales/RomRaider/ecu/standard/ecu_defs.xml - Added a Raw Scaling definition so users can select it and see the table in its natural units as stored in the ROM image - Table Property updated to list all available scalings for the table as well as the Logger parameter ID used for the Logger overlay function - Removed JFontChooser library - Added ability to convert ROM image from 160kB to 192kB - Added ability to convert ROM image from 192kB to 160kB - Added Table axis and data cell interpolation feature - Added support for additional Checksum validation/corrections found in BRZ ROMs - Removed BareBonesBrowser library, now uses existing class - Updated Java 3D libraries to version 1.5.2 - Logger - Fixed Learning Table Values international character support - Added support for PLX SM-AFR Gen 3 - Removed reference to minimum Logger definition XML file version - Add OBD mode 1 Logging support for CAN ECUs using J2534 - Add protocol attribute to user Logging Profiles to indicate OBD and SSM profiles 0.5.7 RC2 (08/28/2013) ---------------------------------- - Logger - Fixed Learning Table Values reading ECU def problem for 6-cyl cars. 0.5.7 RC1 (08/05/2013) ---------------------------------- [1] New Logger features require added parameters in the logger definition file. Therefore the minimum version of logger.xml is 155. A warning will be displayed if the version is below this prompting the user to update. [2] The settings XML file can be stored in the RomRaider directory as an alternate location. This allows multiple customized installations to exist each with their own settings. - Logger - Added feature to read DTC via SSM connection [*1] - Added feature to adjust the global timing and AC on/off idle RPM values [*1] - Added feature to read ECU specific Learning Table Values [*1] - Added feature to allow user to define conversion formulas for Phidget sensors - TXS plugin update: by nitros - changed QueryManager to break TCU queries up as TCU doesn't support long CAN queries - support for signed integer values added [*1] - support for non-contiguous multi-byte parameters added [*1] - corrections to ISO15765 support, fixed debug messages and array index problem. - changed SSM test application to write bytes rather than blocks - changed SSM test application to allow selection of byte or block reads - update PLX sensor types to drop data for unknown sensor address 4032 - force some font styles to plain as Linux seems to use bold as default Operational Notes - Since RomRaider relies on various externally provided classes and vendor libraries, the 64bit Java VM is not supported. The RomRaider installer and Editor will issue warnings if a 64bit Java VM is detected and advise the user to uninstall it and install the 32bit Java VM. It is unlikely that 64bit Java VM will even be supported as all external classes and vendor libraries must be compiled for native 64bit operation. See note 3 for an example. - To log External sensors only, un-select both the ECU and TCU checkbox on the Logger menu bar. Then switch to the Externals tab and check the items to be logged. The log Externals only setting is not retained between logging sessions. - The use of ISO15765 requires a J2534 compliant cable. Since the J2534 specification only defines Windows 32bit systems as a valid platform, Linux systems are not officially supported. When/if a Linux J2534 driver becomes available then support can be enabled for non-Windows platforms. 0.5.6 RC6 (03/24/2013) ---------------------------------- - Editor - fix for various Table Compare operations: by scotthew - added a Java 64bit VM check and warning: by lizzardo [*1] - Logger - fix Logger Close while on any of the MAF, Injector or Dyno tabs: by lizzardo - added a Java 64bit VM check and error then close: by lizzardo [*1] - fix to allow logging of External sensors only (with no ECU connection) [*2] - refactor to allow easier addition of other future Logging protocols - added ISO15765 protocol support on Windows platform [*3] - added a user Setting to Logger to force English US number format in log files - fix for issue #4 (multiple Query Managers could be started) - update 'Log to file' button to switch between 'Start/Stop' in the label - add a rudimentary test app to read some OBD-II parameters [*4] - reformat (shorten) display of Profile and log file names in Logger title bar - Application Installer - added a Java 64bit VM check and warning during installation: by lizzardo [*1] Notes [1] - Since RomRaider relies on various externally provided classes and vendor libraries, the 64bit Java VM is not supported. The RomRaider installer and Editor will issue warnings if a 64bit Java VM is detected and advise the user to uninstall it and install the 32bit Java VM. It is unlikely that 64bit Java VM will even be supported as all external classes and vendor libraries must be compiled for native 64bit operation. See note 3 for an example. [2] - To log External sensors only, un-select both the ECU and TCU checkbox on the Logger menu bar. Then switch to the Externals tab and check the items to be logged. The log Externals only setting is not retained between logging sessions. [3] - The use of ISO15765 requires a J2534 compliant cable. Since the J2534 specification only defines Windows 32bit systems as a valid platform, Linux systems are not officially supported. When/if a Linux J2534 driver becomes available then support can be enabled for non-Windows platforms. [4] - This rudimentary test app ONLY works with J2534 compliant cables and ONLY supports the ISO15765 protocol. It can currently read out the vehicle information and any active DTCs. The app can only be started from a command window in the RomRaider directory using the following syntax: java -cp RomRaider.jar com.romraider.io.j2534.api.TestJ2534IsoTp [j2534dll] where [j2534dll] is a valid J2534 DLL library name, default is to use the Tactrix Openport 2.0 library 0.5.6 RC5 (12/22/2012) ---------------------------------- - Editor - partial fix for Table Compare to another map by scotthew - Logger - fix to handle Registry FILE_NOT_FOUND error response for J2534 device lookup. 0.5.6 RC4 (12/13/2012) ---------------------------------- Maintainability Updates - remove unused imports - enhanced web browser support - use Font.{DIALOG,SANS_SERIF} for maintainability - simplify static method call to Logger.Settings - initialize caseID to avoid null being displayed in ROM tree title Application Installer - changed Release Notes and License shortcut spec in Linux template to be an Application to make them show in the RomRaider menu group - changed Uninstaller commandline and Icon file name in shortcut spec in Linux template 0.5.6 RC3 (11/14/2012) ---------------------------------- - Editor - fix for the overlay of logged data on tables by scotthew - Logger - fixed Linux ZIP install run.sh script, it was failing due to file not found - added missing Phidget & TXS UTEC plug-in files in the installer packages - added detailed Debug list of all ROM ID details for all configured ECU def files - fix for calculation of derived parameters when units of dependents contain symbols - changed some default unit abbreviations such as kph to km/h 0.5.6 RC2 (10/20/2012) ---------------------------------- - Editor - updates to fix a few bugs related to the ROM tree by scotthew - updates to Copy & Paste tables by scotthew - updates to fix ROM tree focus and reflect selected in menus and buttons by scotthew 0.5.6 RC1 (09/29/2012) ---------------------------------- - Logger - TXS plugin refactored to include Tuner Pro by nitros@romraider.forum - Editor - Table toolbar moved from table window and onto main window. Toolbar can now be moved. Updates to multi-thread some major functions. Try this, open a rom, while that ROM is opening open another ROM and then launch the Logger. And while all of this is going on resize the main editor window. It should all be smooth as silk. By scotthew@romraider.forum 0.5.5 RC1 (07/29/2012) (Same as SNAPSHOT 86b338) ---------------------------------- --- Logger --- - Minimum Java version 1.6 (x86) required - Changed LM-2 MTS plugin from event based data reads to fixed interval data reads - TXS plugin refactored to include Tuner Pro by nitros@romraider.forum - Added AEM X-Wifi Controller external plugin - Added Phidgets InterfaceKit external plugin - J2534 API updated to remove dependency on J/Invoke - J2534 API refactored to use JNA 3.4.0 - Removed OpenPort 2.0 specific package (op20) as it is now supported in the J2534 API - J2534 API supports searching all available devices and if none found will default to serial. J2534 settings are stored and loaded through the settings file - Including com4j-x86.dll to ensure it is present in the install directory to avoid write permission issues on Win7 - Created a new J2534DllLocator class based on JNA and removed third-party registry Jar - Added extra LOGGER.debug statements to assist with troubleshooting - Corrected serial connection close() call in all serial plug-ins as exceptions were being thrown - Changed QueryManager logic to try and deal with duplicate log entries caused by high speed logging, it may still need some work - Added Logger definition version to Help->About menu - Updated Dyno control panel to look for cars_def.xml & .dtd in three possible locations: 1 - the directory where the logger.xml file lives (preferred location) 2 - the directory where the user stores their logging profiles 3 - the RomRaider installation directory - Fixed up the Parameter List Show/Hide state when opening the Logger such that the list on each tab is set the same as the last selected tab's state --- Editor --- - Fixed Test App's ability to walk through addresses and cross the 0xf7fff 0xf8000 boundary correctly - scotthew@romraider.forum Added the ability to compare all tables in two ROM images Usage: - Open one or more ROM images (The same image can be compared to itself. Will not do much but show "Images are equal.") - Select Edit->Compare Images... - Select the two images to compare and click the compare button - Results are displayed in the results pane - scotthew@romraider.forum Added ability to save as repository. This basically dumps the tables into a file structure represented by the categories and saves the tables as a text file. Use this for tracking changes made to ROMs using a revision control system. - scotthew@romraider.forum Added ability to change the clipboard format. Options are Default, Airboy's, and Custom. Custom formats are specified in the settings.xml file 0.5.4b RC1 (10/28/2011) ----------------------- --- Logger --- - TXS Tuner Wideband plugin added courtesy of, nitros - Added support for ECU/TCU Switch filtering - Added (msec) designation to logged CSV column heading - Added support for sorting the Selected? & Description parameter list entries - Added support for convertors on External data items (F/C, lambda/AFR, etc.) - Added instance 0 of all defined PLX Sensors according to their documentation - Added support for additional Innovate MTS LM-2 sensors. Sensors are now loaded dynamically when the Logger starts. Sensor units are set via LogWorks. Wideband errors are reported as the negative value of the error number. For example, if an LC-1 is in need of calibration -3 will be reported to the Logger. See MTSSensorInputFunction.java for more state values. - Updated library COM4J to version: com4j-20110322. This affects Innovate MTS and Tactrix Openport 2.0 support. - Added a button to Un-select ALL selected parameters on all tabs. Selections can be restored by reloading the current profile or loading a different profile. - Moved the Fast Poll checkbox to a selection item in the Settings menu (selected by default). The polling state is reported in the queries/sec status display. - Added a Debugging Level selection option to the Help menu. The setting is saved and restored between sessions. INFO should be the normal state to keep the rr_system.log file in-check. - Moved the COM port Auto Refresh checkbox to the Settings menu. - Added a Logger startup Progress Bar as loading plugins sometimes takes time. - Added colour to "Log to File" button. Red when recording and green when not. * Button colours may not appear correctly as this is platform dependent. Colours may show as a border rather than a fill. Also changed the colours used for the connection state: * Red Square = recording to file (used to be green) * Green = connected and ready to record (used to blue) * Blue = connection to ECU in progress (used to be red) * Red with X = disconnected (used to be red) - Added colour to "Un-select ALL" button. Yellow so it stands out. * Button colours may not appear correctly as this is platform dependent. Colour may show as a border rather than a fill. - Moved settings.xml & profile_backup.xml to the /.RomRaider/ directory under the users home directory. - Added support to reset the TCU. The reset target is selected via the action bar Checkbox items ECU or TCU just like logging. --- Editor --- - Set JInternalFrame.isPalette in TableFarme.java so table titles are visible on Mac OS. - Added a Checksum recalculation option when saving ROM images that have a bad Checksum (re: Diesel ROMs seem to have an invalid fifth Checksum) 0.5.3b RC10 (09/12/2011) ------------------------ --- Editor --- - Added support for multiple-state switches. Switch Tables will now use Radio Buttons rather than a Checkbox. - Added ECU definition data validation for Switch Tables. If the ROM image data does not match one of the switch states according to the definition then a warning is presented and the table is locked from editing. - Added ROM Checksum validation on image open for 32 bit ROMs. An ERROR message is presented warning not to use the ROM image as it may be corrupt. - Added ROM Checksum calculation for 32 bit ROMs. Upon file save the new Checksums (if not previously disabled) are written to the ROM. - Added a ROM Edit Stamp to 32 bit ROMs consisting of the YYMMDD and an incremental count value. This Edit Stamp is displayed in the View->ROM properties menu item. - Fixed the missing Table Tree problem when running RomRaider on systems using IcedTea or OpenJDK JVM. --- Logger --- - Added more selections to the Right-click menu associated with the LogFile text field. - Made Fast Polling the default mode for the Logger connection. 0.5.3b RC9 (06/30/2011) ----------------------- --- Logger --- - log4j.properties updated with new name for romraider.log --> rr_system.log - new logger field to allow arbitrary text to be added to log file name (right- click on field for options) - Tech Edge plugin updates - PLX plugin update to ignore unsupported data items - Innovate MTS plugin updated to ignore unsupported data items - Logging data error handling improved and hang condition eliminated - Logging performance improved (fast poll may not work with 16 bit ECU, untested) - Log file field value delimiter changed from comma to semicolon when values use comma as decimal place holder - Start of support for international numbers and text 0.5.3b RC8 (05/14/2011) ----------------------- --- Logger --- - Added support to log from ECU or TCU (not both at the same time, yet) - New AEM protocol support added (AEM2 plugin works at 19200 baud and reports Lambda values) - New Tech Edge support added (currently only supports data format 2.0) 0.5.3b RC7 (12/21/2010) ----------------------- --- Editor --- - Fixed Compare map scroll list - Added support for sign integer data (used in diesel ROMs) --- Logger --- - Improved serial connection handling - MRF Stealth Gauge support added - Added saving parameter list show/hide to settings - Added USER input read ability for ZT2 - Added check box to enable/disable COM port refreshing and save the setting 0.5.3b RC6 (05/02/2009) ----------------------- --- Logger --- This RC includes the new Road Dyno/ET tab, version 16. To use the Road Dyno: - Set the Mode button to Dyno - Clear all parameters from the other tabs to achieve the best data resolution. - On the Dyno tab, select your vehicle and adjust the tire size and gear you will be using. - Once set, press the Record Data button. - With the button pressed setup to do your WOT run, no need to hurry. - Hold WOT run to redline. As soon as WOT is no longer detected the graph will be updated with your estimated wheel power and torque. - Adjust temperature and humidity if they are not accurate and "recalculate" the results. - Smoothing, lower is more smooth and higher is less smooth. - Right click on the graph to Save as... - If you wish to average two or more consecutive runs, press the Record Data button again and repeat the WOT run. At the end of each run the datasets will be combined and the results displayed. - A Reference Trace can be Saved and displayed at any time for comparison. - The Clear button will delete all recorded data for a fresh start. To use the ET feature: - Set the Mode button to ET - Clear all parameters from the other tabs to achieve the best data resolution. - On the Dyno tab, select the vehicle you will be using. - Once set and the vehicle is stationary, SPEED = 0, press the Record ET button. - With the button pressed complete your 1/4 mile run. - As soon as 1/4 mile distance is covered the graph will be updated with your elapsed times and speeds. - Right click on the graph to Save as... - Or Save a Reference Trace of your times to a text file. 0.5.3b RC5 (11/29/2009) ---------------------- --- Logger --- - 14Point7 NAW_7S UEGO support added - Improved serial connection handling 0.5.3b RC4 (10/31/2009) ---------------------- --- Logger --- - LM-2 MTS support added (possibly flaky!) - Consolidated Innovate wideband serial plugins (LC-1, LM-1, LM-2) - Plugin ports automatically saved and reloaded 0.5.3b RC3 (10/18/2009) ---------------------- --- Editor --- - Dump system props to log at startup --- Logger --- - Update Zeitronix item labels - Update installer config 0.5.3b RC2 (10/17/2009) ---------------------- --- Logger --- - PLX and Zeitronix sensor support added - AEM UEGO support improved 0.5.2b (02/07/2009) ---------------------- --- Editor --- - ECU def config check added --- Logger --- - Set OP2.0 loopback=1 - Logger def config check added 0.5.1b (12/24/2008) ---------------------- --- Editor --- - Table compare bug fixed. - Table drag speed improvements (disabled D3D use). --- Logger --- - Removed all UTEC integration. 0.5.1b RC5 (11/17/2008) ---------------------- --- Logger --- - J2534 api tweaks. - External sensor connection handling updated. 0.5.1b RC4 (10/9/2008) ---------------------- --- Editor --- - Table compare bug fixed. - Debug save mode enabled by default. - Already running detection port changed to 50001. --- Logger --- - Some refactoring around serial port handling. - Fix display of unknown rom ids. - Add config item for logger definition location. 0.5.1b RC3 (9/25/2008) ---------------------- --- Logger --- - OpenPort 2.0 cable integration 0.5.1b RC2 (6/14/2008) ---------------------- --- Editor --- - Ramtune Test app menu item name changed to SSM - Fixed save/restore of cell height/width bug --- Logger --- - Vertical control panel added for tab specific functions - Parameter list converted from split panes to tabs and widened by default - Last open tab now remembered - Icon added to log to file button - Fullscreen mode via startup parameter '-logger.fullscreen' 0.5.1b RC1 (6/7/2008) --------------------- --- Editor --- - Vertical axis label restored on 3D tables --- Logger --- - Connection handling updated - User profile loading updated - Hide/show parameter list (F11) on data, graph, dash tabs - Switchable (F12) dash gauge styles - Scrollable dash pane - Latest data point on MAF and injector scaling tabs displayed as a different colour. 0.5.0b (5/1/2008) ----------------- --- Editor --- - Minor bug fixes - RAMTune test application --- Logger --- - Plugin interface added including plugins for, - Innovate LC-1 - Innovate LM-1 - AEM UEGO - UTEC - New MAF scaler tab - New injector scaler tab - Reset ECU 0.4.1b (2/8/2007) ----------------- --- Tuning --- - Fix frame sizes too small on 2d tables - Fix switch tables displaying wrong icon in table tree --- Datalogging --- - Autoconnect - Reset, disconnect buttons - Reset data buttons per tab - Updated dash tab with warning levels (warning levels not currently saved to profile) - Fixed "Manifold Relative Pressure (Corrected)" parameter - Fixed profile save/load problems - ECU id display in status bar - Updated address format in logger.xml (length attribute added to replace multiple tags. length defauilts to 1 if not specified) - Autodetection of ecu specific parameters via new tags in logger.xml (IAM, engine load) - ECU connection status indicator added to interface (stopped, connecting, reading data, logging to file) - Auto filtering of parameter list based on ECU init response (should only display now what your car says it supports) - Enable defogger switch based file logging via menu bar (don't need to select it in switch list anymore) - Defogger switch is only logged to file when explicitly enabled - Absolute timestamp option added for file logging - Relative timestamp now reset to zero at the beginning of each log file (unless absolute timestamp is selected) - Graph tab color scheme updated - Enhancements to the map overlay feature, including display of the live data and overlay of the live data values on the map cells. - Tooltips added to parameter list showing parameter description (not all parameters have a description yet though) - General logger parameter updates/additions 0.4.0b (11/10/2006) ------------------- - Add file associations - Ability to view (but not modify) tables above userlevel - Add link to latest ECU definitions - Fix switch (CEL fix) inheritance - Fix table ordering in child ROMs - Fix table level display in property panel - Fix label fonts on 3D tables - Logging - 3D graphing - Interpolating (map smoothing) 0.3.2b (8/12/2006) ------------------ - Installer/Shortcuts - Add status bar - Add support for hex ID strings for Mitsubishi support - Fix goofy behavior of increase/decrease at limits - Add multiply values function - Improve exception handling in XML parser - Add lockable tables via ECU definitions - Rearrange 3D table labels - Improve datacell colorize method - Add limits to table values in XML - Fix exiting through menu not saving settings - Add ECU Definition Manager 0.3.1b (7/11/2006) ------------------ - Change year attribute to string from int - Fix incrementing in compare mode - Fix refresh tables working improperly with multiple ROMs open - Update table property panel - Fix float values not incrementing properly in axiis - Fix values not incrementing if increment amount is less than LSB - Add option whether to display tables higher than userlevel - Add option whether to save changes made to debug tables - Fix clicking on ROM tree opening/closing wrong tables - Fix switch tables not compensating for RAM - Fix many memory leak problems - List tables above userlevel, but disabled - Color debug tables red - Add "version" tag to settings - Show release notes on first run - Remove unnecessary variables from settings XML - Add name and description to CEL/checksum fix tables - Fix "(null)" text on static 2D axiis - Remove table name from bottom of 2D table - Allow single clicking to open tables (via settings) - Add fine adjustment values to ECU definition - Fix map copy/paste - Increment affects real instead of binary value - User levels - Fix definition parser rounding incrementby values - Improve table properties display - Fix byte/real conversion validation 0.3.0b (7/2/2006) --------------------------------------- - Finish map comparing implementation 0.2.93a Private Test Release (7/1/2006) --------------------------------------- - Added "switch" table type 0.2.92a Private Test Release (7/1/2006) ---------------------------------------- - Fixed squares appearing instead of some float values - Fixed exception when entering decimals in coarse value - Fixed set value field being cast to integer instead of decimal - Fixed progress bar not closing on errors - Pressing "." now focuses set value field 0.2.91a Private Test Release (6/30/2006) ---------------------------------------- - Fixed memory usage issues - Added performance and other memory optimizations 0.2.90a Private Test Release (6/30/2006) ---------------------------------------- - Added 32-bit ECU (float) support 0.2.7.4b (5/09/2006) -------------------- - Fixed 16-bit 3D tables saving improperly - Added compare to original value function 0.2.7.3b (4/17/2006) -------------------- - Fix border colors not showing changes from keyboard - Add progress indicators - Remove table definition generator - Fix refresh button closing images with same filename - Fix border/background of static axiis - Fix rounding problems causing false conflicts for conversion expressions - Fix set value not updating borders - Reset default settings option - Fix cell border not saving - Improve warning messages - Fix ECU definition file settings not saving - Fix last image directory resetting - Fix updated cell border not updating 0.2.7.2b (4/12/2006) -------------------- - Fixed close all images 0.2.7.1b (4/12/2006) -------------------- - Fixed ECU definitions not saving - Fixed last image directory not saving - Fixed colors not saving - Fixed increased/decreased cell borders not updating 0.2.7b (4/12/2006) ------------------ - Replace serialized settings object with XML - Settings panel - Custom sizes/fonts/colors for tables - Fix blue 2D table axiis - Fix exception when clicking on table list - Expression/to_byte conflict warning - Rename packages to conventional lowercase - Improve refresh method when saving - Improve exception reporting - Implement "obsolete" tag -- set up wiki with ROM revision info - Group tables by category - Fix descriptions not working - Fix 2D table navigation 0.2.6b (4/5/2006) ----------------- - Shortcut keys - Improve display of tables too large for window (MDI) - Improve exception reporting - Improve saved window position on exit (panel size, maximized) - Remove "copy" from table menu -- its in the edit menu - Fix vertical overhead on table size for new graphical buttons - Fix rounding issues with set value - Fix ctrl-click on tables - Resize cells to make best use of screen - Prevent simultaneous selection of axiis and table values - Map copying - Graphical icons - Cascade windows (MDI) - Fix table frame JScrollPane (MDI) 0.2.5b (3/28/2006) ------------------ - Import tables by single address - Refresh image button - Table properties - Add "obsolete" tag for images with more recent revisions - Fix application not closing files after reading - Add file extensions to open/save dialog (HEX, BIN) - Fix parser searching by XML ID instead of internal storage ID - Image properties - Show positive (red) and negative (blue) value changes on tables BUG FIXES: - Decrement (fine) increments - Files not closing after being read - Set value rounds goofy - 1D tables not colorizing properly - 2D tables not working properly - Set value field shows negative numbers 0.2.4a (3/21/2006) ------------------ - "Base" attribute for extending/duplicating tables - "Omit" attribute not required to omit tables -- just set storageaddress to "0" - Fine and coarse adjustment of values - Direct value input - Support for ROMs with or without RAM sectors 0.2.3a (2/27/2006) ------------------ - ECU definitions including each other (endless loop) is now handled - "Omit" attribute allows incomplete tables to be removed from inheriting definitions - Nested includes (includes more than 1 definition deep) tested and working properly 0.2.2a (2/26/2006) ------------------ - Include support in XML definitions (exception handling not yet implemented!) 0.2.1a (2/13/2006) ------------------ - Handles storage addresses that are out of range - Fixed conflicting parent/child table sizes (done) - Replaced "" menu with "Table" -- makes it more obviously a menu - Fixed 3D table sizing problem - Fixed colorizing exception - Fixed backwards endians - Fixed storage address out of range exception - Improved close image method .20a (2/11/2006) ---------------- -Completely rewritten -XML ECU definitions -View multiple images and tables .14a (11/26/2005) ------------------ -Improved axis cell modification -Fixed absolute value calculations .13a ----- -Revised text entry of values -Added EUDM WRX support -Improved multiple cell selection -Improved axis cell modification -Axis cell changes can be saved Supported ECU Versions/Version Added - Deprecated as of version .20a. ECU versions are now defined in ecu_defs.xml. ---------------------- 2004/2005 USDM WRX: -A4TF300E .13a -A4TF400E .13a -A4TF800E .13a -A4TF500F .13a -A4TF510F .13a -A4TF800F .13a 2002/2003 USDM WRX: -A4TC300L .13a -A4SGC00C .13a -A4SGD10C .13a -A4SG900C .13a 2003 EUDM WRX: -A4TE001G .13a